USA FLAG

180kW DC Chargers

Features

  • Single and Dual Connectors
  • Parallel Charging
  • All-One-Format – Easy to Install
  • Liquid Cool Connectors for High Currents
  • RFID Reader
  • Optional Credit Card Reader
  • OCPP 1.6J Compliant
  • FRU Onboard Diagnostics, Easy to Service
  • UL Certified
180 kW DC Charger

Specifications

Product # TP5-180-480 HPC-180-480
Maximum Power 180 kW
Output Voltage 150 – 1000 VDC
Max Output Current upto 200A upto 500A
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 240A || 300A
Power Factor >0.98
Efficiency >94%
Connector Options CCS1 and CCS1
CCS1 and CHAdeMO
CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 200A Liquid Cooled 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 180kW (Max: 200A) 1 x 180kW (Max: 450A)
Parallel Mode 2 x 90kW (Max: 200A) 2 x 90kW (Max: 250A)
Connector cable length CCS1 – 13 ft (4 m) | CHAdeMO – 16ft (5 m)
Weight 880 lbs (400 kg) 950 lbs (430 kg)
Dimensions (L x D x H) 29.5‘’ x 26.5’’ x 73’’
Charging Protocol Standards Mode 4, IEC-61851, ISO-15118, DIN 70121
Mode 4, CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 7’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007,EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button