Product # |
TP5-160-480 |
HPC-160-480 |
Maximum Power |
160 kW |
Output Voltage |
150 – 1000 VDC |
Max Output Current |
upto200A |
upto400A |
Input Voltage || Frequency |
480V (3P + N + PE) || 60 Hz |
Input Current || Breaker Rating |
215A || 300A |
Power Factor |
>0.98 |
Efficiency |
>94% |
Connector Options |
CCS1 and CCS1 CCS1 and CHAdeMO |
CCS1 CCS1 and CCS1 CCS and CHAdeMO |
CCS Cable |
200A |
400A Liquid Cooled |
CHAdeMO Cable |
125A (Standard) Or 200A |
Cycle Mode |
1 x 160kW (Max :200A) |
1 x 160kW (Max : 400A) |
Parallel Mode |
2 x 80kW |
2 x 80kW |
Connector cable length |
CCS – 16 ft (5 m) CHAdeMO -16ft (5 m) |
CCS – 13 ft (4 m) CHAdeMO -16ft (5 m) |
Weight |
880 lbs (400 kg) |
950 lbs (430 kg) |
Dimensions (L x D x H) |
29.5‘’ x 26.5’’ x 73’’ |
|
Charging Protocol Standards |
Mode 4, IEC-61851, ISO-15118, DIN 70121 Mode 4, CHAdeMO 0.9, 1.0 |
Insulation (input – output) |
>2.5 kV |
Ingress Protection |
NEMA 3S, IK10 |
Operating temperature |
-22 deg F to 131 deg F (-30 deg C to 55 deg C) |
Altitude |
< 6600ft (2000m) |
Working || Storage Humidity |
≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display |
7’’ touch screen |
Communication Protocol |
OCPP 1.6J |
Access Control |
RFID: ISO/IEC 14443A/B || Credit Card – Optional |
Power Electronics Cooling |
Air Cooled |
Regulatory Compliance |
UL-2202 || EMC: EN 61000-6-1:2007,EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication |
Ethernet, 4G/Wi-Fi |
Electrical Safety: GFCI |
RCD 20 mA Type A |
Electrical Safety: Surge Protection |
20 kA |
Electrical Safety General |
Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short |
Output power disabled when output is short circuited |
Electrical Safety Temperature |
Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop |
Disables output power with emergency stop button |