Rated power |
TP5-30-480 |
Input |
480VAC (3P+N+PE), 60Hz |
Output Voltage |
150-1000VDC |
Output Current |
0 to 100A |
FLA || Breaker Rating |
40A || 64 A |
Power factor |
> 0.98 |
Efficiency |
>94% |
Connectors |
CCS1 Or CHAdeMO |
Connector cable length |
5m |
Weight |
176 lbs (80kgs) |
Dimensions (L x D x H) |
21’’ x 12’’ x 27’’ |
Charging Protocol Standards |
Mode 4 – IEC-61851, ISO-15118, DIN 70121 Mode 4 – CHAdeMO 0.9, 1.0 |
Insulation (input – output) |
>2.5 kV |
Ingress Protection |
NEMA 3S, IK10 |
Operating temperature |
-22 deg F to 131 deg F (-30 deg C to 55 deg C) |
Altitude |
< 6600ft (2000m) |
Working || Storage Humidity |
≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display |
7’’ touch screen |
Communication Protocol |
OCPP 1.6J |
Access Control |
RFID: ISO/IEC 14443A/B |
Power Electronics Cooling |
Air Cooled |
Regulatory Compliance |
UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication |
Ethernet, 4G/Wi-Fi |
Electrical Safety: GFCI |
RCD 20 mA Type A |
Electrical Safety: Surge Protection |
20 kA |
Electrical Safety General |
Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short |
Output power disabled when output is short circuited |
Electrical Safety Temperature |
Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop |
Disables output power with emergency stop button |