USA FLAG

240KW DC CHARGER

Features

  • Single and Dual Connectors
  • Parallel Charging
  • All-One-Format – Easy to Install
  • Liquid Cool Connectors for High Currents
  • RFID Reader
  • Optional Credit Card Reader
  • OCPP 1.6J Compliant
  • FRU Onboard Diagnostics, Easy to Service
  • UL Certified
3
240 kW DC Charger

Specifications

Product # HPC-200-480
Maximum Power 240 kW
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 215A || 300A
Output Voltage 150 – 1000 VDC
Max Output Current upto 500A
Power Factor >0.98
Efficiency >94% at nominal output power
Connector Options CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 200kW (Max: 500A)
Parallel Mode 1 x 120kW (Max: 250A)
Charing Standard – 1 Mode 4 – IEC-61851, ISO-15118, DIN 70121
Charing Standard – 2 Mode 4 – CHAdeMO 0.9, 1.0
Connector cable length CCS1 – 13 ft (4 m) | CHAdeMO – 16ft (5 m)
Weight 950 lbs (430 kg)
Dimensions (L x D x H) 41‘’ x 35’’ x 74’’
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 7’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card – Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button