Product Number |
TP4-200-400 |
Maximum Power |
200 kW |
Input Voltage || Frequency |
400VAC / 480VAC (3P+N+PE), 50/60Hz |
Input Current || Breaker Rating |
0 to 300A |
Output Voltage |
150 – 750 VDC |
Output current |
0 to 300A (200A | 250A Limited by Connector) |
Power factor |
> 0.98 |
Efficiency |
>94% at nominal output power |
Connectors |
Dual GB/T Dual CCS |
Cyclic Charge Mode |
CCS – 200 A || GB/T – 250A |
Cycle Mode |
500A |
Parallel Charge Mode (Optional) |
100 kW per Port |
Connector cable length |
5m |
Weight |
430kgs |
Dimensions (L x D x H) |
760 mm x 673 mm x 1800mm |
Charging Protocol Standards |
Mode 4 – IEC-61851, ISO-15118, DIN 70121 Mode 4 – GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) |
>2.5 kV |
Ingress Protection |
IP54, IK10 |
Operating temperature |
– 22 F to 131 F ( 30 C to 55 C ) |
Altitude |
< 2000m |
Working || Storage Humidity |
≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display |
7’’ touch screen |
Communication Protocol |
OCPP 1.6J |
Access Control |
RFID: ISO/IEC 14443A/B || Credit Card – Optional |
Power Electronics Cooling |
Air Cooled |
Regulatory Compliance |
CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication |
Ethernet Standard 4G || Wi Fi (Optional) |
Electrical Safety: GFCI |
RCD 30 mA Type A |
Electrical Safety: Surge Protection |
20 kA |
Electrical Safety General |
Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short |
Output power disabled when output is short circuited |
Electrical Safety Temperature |
Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop |
Disables output power with emergency stop button |